Three Phase DC250V-800/AC Input Solar Pumping Inverter Driving AC Pump Output 3000W 380V

Model NO.: SI200 Series
Output Frequency: 0 ~ 650Hz (off 0~50Hz)
Max Input DC Voltage: 400VDC & 800VDC
Min Input Voltage, at Mpp [V]: 180V & 350V
MPPT Voltage Range Recommended: 250~350VDC & 450~600VDC
Vibration: Less Than 5.9m/S (0.6g)
Model: RS485-Based Real-Time Remote Monitoring System
Trademark: Janson Controls
Transport Package: Carton
Origin: China
HS Code: 8501109990
Model NO.: SI200 Series
Output Frequency: 0 ~ 650Hz (off 0~50Hz)
Max Input DC Voltage: 400VDC & 800VDC
Min Input Voltage, at Mpp [V]: 180V & 350V
MPPT Voltage Range Recommended: 250~350VDC & 450~600VDC
Vibration: Less Than 5.9m/S (0.6g)
Model: RS485-Based Real-Time Remote Monitoring System
Trademark: Janson Controls
Transport Package: Carton
Origin: China
HS Code: 8501109990
Basic principle

Si200 solar pumping system can provide water for remote areas lacking of electricity or places where the electricity supply is unstable. PV pump controller can convert the DC power from solar panels to AC power so to drive various kinds of pumps.System enables continiously pumping when in good weather. System is not equipped with strorage battery devices, it is suggested that pumping the water to conservation pool
for future use.Water source could come from river, lake,well,or other natural water source or special soucre.System enables application of floating switch in the conservation pool or water tower to control the operation of pumps. Low water level probes can be installed in the well to detect the water level of the well in order to stop the pumps when the well in low water level. Diagram 1 is a typical SI200 PV pumping
system. The main parts and compenents of this system is after diagram 1.

Three Phase DC250V-800/AC Input Solar Pumping Inverter Driving AC Pump Output 3000W 380V

SI200 PV pumping system is composed of following parts:
A Solar panels ,
B , DC circuit braker or disconnector
C , SI200 PV pump controller
D , Pump
E , well water level switch(optional)
F , water tower water level switch(optional)
SI200 PV pump controller can start the pump softly and is consistent with the electricity
coming from the changes providing by solar panels. The advantage of soft starting is
avoid surge or power surges when the pump or motor are in the process of starting,whi-
ch reduce the loss of motor and pumping system.

Three Phase DC250V-800/AC Input Solar Pumping Inverter Driving AC Pump Output 3000W 380V
SI200 PV Pump Controller input/output parameter
SI200-2SXXX
 
Model SI200-2S-0.7 SI200-2S-1.5 SI200-2S-2.2
PV array input parameter
Max input voltage(V) DC 450V
Min input voltage(V) DC 180V
Recommended voltage(mpp) DC 280~360V
Recommended PV power(Kw) 0.9 ~1.2 1.8~2.4 2.7~3.5
Spare AC generator
Input voltage ( V ) Singel phase AC 200-240(+10%)
Max current(A) 8.2 14 23
Generator capacity(kVA) 1.5 3 4
Output parameter
rated output voltage 3-phase AC 200-240V
Max current(A) 4.7 7.5 10
Rated output power(kW) 0.75 1.5 2.2
Output frequency 0~50Hz/60Hz
 
SI200-4TXXX Input/output parameter
Model SI200-4T-2.2 SI200-4T-3.7 SI200-4T-5.5 SI200-4T-7.5
PV array input parameter
Max input voltage(V) DC 800V
Min input voltage(V) DC 350V
Recommended
voltage(mpp)
DC 500~600V
Recommended
PV power(Kw)
2.7 ~3.5 4.8~6.4 6.6~8.8 9~12
Spare AC generator
Input voltage ( V ) 3-phase AC 380/400/415/440V(+15%)
Max current(A) 5.8 10.5 14.6 20.5
Generator capacity(kVA) 4 5.9 8.9 11
Output parameter
rated output voltage 3-phase AC 380/400/415/440V(+15%)
Max current(A) 5.1 9 13 17
Rated output power(kW) 2.2 3.7 5.5 7.5
Output frequency 0~50Hz/60Hz
             
 
Model SI200-4T-11 SI200-4T-15 SI200-4T-18.5 SI200-4T-22
PV array input parameter
Max input voltage(V) DC 800V
Min input voltage(V) DC 350V
Recommended
voltage(mpp)
DC 500~600V
Recommended
PV power(Kw)
13.2~17.6 18~24 22.2~29.6 26.4~35.2
Spare AC generator
Input voltage ( V ) 3-phase AC 380/400/415/440V(+15%)
Max current(A) 26 35 38.5 46.5
Generator capacity(kVA) 17 21 24 30
Output parameter
rated output voltage 3-phase AC 380/400/415/440V(+15%)
Max current(A) 25 32 37 45
Rated output power(kW) 11 15 18.5 22
Output frequency 0~50Hz/60Hz
                 
 
 
 
Model SI200-4T-30 SI200-4T-37 SI200-4T-45 SI200-4T-55
PV array input parameter
Max input voltage(V) DC 800V
Min input voltage(V) DC 350V
Recommended
voltage(mpp)
DC 500~600V
Recommended
PV power(Kw)
36~48 44~59.2 54~72 66~88
Spare AC generator
Input voltage ( V ) 3-phase AC 380/400/415/440V(+15%)
Max current(A) 62 76 92 113
Generator capacity(kVA) 40 57 69 85
Output parameter
rated output voltage 3-phase AC 380/400/415/440V(+15%)
Max current(A) 60 75 91 112
Rated output power(kW) 30 37 45 55
Output frequency 0~50Hz/60Hz
             
 
Model SI200-4T-75 SI200-4T-90 SI200-4T-110 SI200-4T-132
PV array input parameter
Max input voltage(V) DC 800V
Min input voltage(V) DC 350V
Recommended
voltage(mpp)
DC 500~600V
Recommended
PV power(Kw)
90~120 44~59.2 132~176 159~211
Spare AC generator
Input voltage ( V ) 3-phase AC 380/400/415/440V(+15%)
Max current(A) 157 180 214 256
Generator capacity(kVA) 114 134 160 192
Output parameter
rated output voltage 3-phase AC 380/400/415/440V(+15%)
Max current(A) 150 176 210 253
Rated output power(kW) 75 90 110 132
Output frequency 0~50Hz/60Hz
             
 
 
 
 
Model SI200-4T-160 SI200-4T-200 SI200-4T-220 SI200-4T-250
PV array input parameter
Max input voltage(V) DC 800V
Min input voltage(V) DC 350V
Recommended
voltage(mpp)
DC 500~600V
Recommended
PV power(Kw)
192~256 240~320 264~352 300~400
Spare AC generator
Input voltage ( V ) 3-phase AC 380/400/415/440V(+15%)
Max current(A) 307 385 430 468
Generator capacity(kVA) 231 250 280 355
Output parameter
rated output voltage 3-phase AC 380/400/415/440V(+15%)
Max current(A) 304 377 426 465
Rated output power(kW) 160 200 220 250
Output frequency 0~50Hz/60Hz
             
 
Model SI200-4T-280 SI200-4T-315 SI200-4T-355 SI200-4T-400
PV array input parameter
Max input voltage(V) DC 800V
Min input voltage(V) DC 350V
Recommended
voltage(mpp)
DC 500~600V
Recommended
PV power(Kw)
192~256 240~320 264~352 300~400
Spare AC generator
Input voltage ( V ) 3-phase AC 380/400/415/440V(+15%)
Max current(A) 525 590 665 785
Generator capacity(kVA) 396 445 500 565
Output parameter
rated output voltage 3-phase AC 380/400/415/440V(+15%)
Max current(A) 520 585 650 725
Rated output power(kW) 280 315 355 400
Output frequency 0~50Hz/60Hz
             
Note:
 

Three Phase DC250V-800/AC Input Solar Pumping Inverter Driving AC Pump Output 3000W 380V

Three Phase DC250V-800/AC Input Solar Pumping Inverter Driving AC Pump Output 3000W 380V

In order to ensure continuous supply water, user can manual switch the SI200 PV pumping system to the standby AC power supply when the light is insufficient or rainy weather. When switching, DC and AC power interlock need to be ensured. Alternate AC  power not only can be local network but also can be diesel generator (Please refer to 2.4.3 input and output parameter table).

Note:
At any moment, there is only one kind of power can be input, otherwise, it may lead to controller failure.

Three phase 380 VAC Alternate AC power supply, for example, wiring diagram such as following:

Three Phase DC250V-800/AC Input Solar Pumping Inverter Driving AC Pump Output 3000W 380V

If pump motor voltage is three phase 220-240VAC, the single phase 20VAC alternate power supply L/N wire need to connect to the controller main terminal R/T.


Our Service:

                   
1.   Can I get some samples?
Yes, Sample order is available for quality check and market test .But you have to pay for it .
2.   What's delivery time?
It usually takes about 3-5 working days for small order and 10-15 days for big order .
3.   What's your payment terms?
We usually accept all kinds of payment terms .Such as T/T,L/C, Western Union.Cash.
4.   What's your warranty terms?
We offer 24 months warranty time .
5.   Do you have the products in stock?
Depends on your request ,We have standard models in stock. Some special products and big order will be newly produced according to your order .
6.   Can I mix different power in one container .
Yes ,Different models can be mixed up in one container ,even one order .
7.   How does your factory do the quality control?
Quality is priority ,we always attach the importance to quality control from the beginning to the end of the production .every product will be fully assembled and carefully tested before packing and shipping .
8.   Can you sell spare parts ?
If you are using our products .we can sell spare parts to you . But we couldn't sell the half-finished products.
9.I would like to know if you have a partner for export?
Yes .We have the right to export and can sell electrical product all over the world..
10. Can you make the inverter and soft starter control boards (switchgear)?
Yes. We have a lot of experience to design frequency inverter and soft starter cabinet according to your request,and our factory can do soft starter by ourselves.
11.Can the inverter connect with computer?
Yes .All inverters have built-in RS485 port .and support Modbus communication protocol. 
12.How can I trust you ?
Our company has been audited and approved ISO9001,CE.CCC. Assessment report will could be sent to you by e-mail. and we will take all the responsibility once problem during warranty time.
  Basic principle

Si200 solar pumping system can provide water for remote areas lacking of electricity or places where the electricity supply is unstable. PV pump controller can convert the DC power from solar panels to AC power so to drive various kinds of pumps.System enables continiously pumping when in good weather. System is not equipped with strorage battery devices, it is suggested that pumping the water to conservation pool
for future use.Water source could come from river, lake,well,or other natural water source or special soucre.System enables application of floating switch in the conservation pool or water tower to control the operation of pumps. Low water level probes can be installed in the well to detect the water level of the well in order to stop the pumps when the well in low water level. Diagram 1 is a typical SI200 PV pumping
system. The main parts and compenents of this system is after diagram 1.

Three Phase DC250V-800/AC Input Solar Pumping Inverter Driving AC Pump Output 3000W 380V

SI200 PV pumping system is composed of following parts:
A Solar panels ,
B , DC circuit braker or disconnector
C , SI200 PV pump controller
D , Pump
E , well water level switch(optional)
F , water tower water level switch(optional)
SI200 PV pump controller can start the pump softly and is consistent with the electricity
coming from the changes providing by solar panels. The advantage of soft starting is
avoid surge or power surges when the pump or motor are in the process of starting,whi-
ch reduce the loss of motor and pumping system.

Three Phase DC250V-800/AC Input Solar Pumping Inverter Driving AC Pump Output 3000W 380V
SI200 PV Pump Controller input/output parameter
SI200-2SXXX
 
Model SI200-2S-0.7 SI200-2S-1.5 SI200-2S-2.2
PV array input parameter
Max input voltage(V) DC 450V
Min input voltage(V) DC 180V
Recommended voltage(mpp) DC 280~360V
Recommended PV power(Kw) 0.9 ~1.2 1.8~2.4 2.7~3.5
Spare AC generator
Input voltage ( V ) Singel phase AC 200-240(+10%)
Max current(A) 8.2 14 23
Generator capacity(kVA) 1.5 3 4
Output parameter
rated outpu

spline roller

This screen rolling tool is constructed from PP. It features convex and concave rollers with a plastic handle. This tool is used to install fiberglass screen fabric and vinyl spline into window screen frame. Spark surface design make the holding more easy, which enhance your operation to seal the spline.
As the professional insect screen supplier, we would like to cooperated with consumer from all the world to develop more tool, to make sure the screen window/door installing become more easy.


Insect Screen Tool

Insect Screen Tool,Plastic Fabric Sun Shade Net,Shade Sail,Safety Net

Huanghua Techo Building Material Co., Ltd. , https://www.insectsscreen.com